Summary
This Preliminary information communicates to the dealer technician diagnostic tips for a vibration concern at low engine speeds. If using these diagnostics shows root cause of the vibration to be the transmission torque converter the torque converter should be replaced.
6 Affected Products
Vehicles
MAKE | MODEL | YEAR |
CHEVROLET | COLORADO | 2019-2021 |
GMC | CANYON | 2019-2021 |
Condition
Customers may comment on a vibration at idle while the transmission is in drive or reverse at 800 to 1000 RPM. The vibration may be more noticeable in reverse and during cold starts. Some customers may comment the vehicle has a short vibration during a launch.
Cause
The cause of this concern may be internal to the torque converter.
Parts Information
Description | Part Number | QTY |
Torque Converter | 24288046 | 1 |
SEOCONTENT-START
Bulletin No.: PIP5743A Published date: 04/6/2021 Preliminary Information PIP5743A 2.5L LCV 6L50 MYB Rough Idle Or Vibration While In Gear After A Cold Start 800 to 1000 RPM And Or A Short Vibration At A Launch Models Brand: Chevrolet GMC Model: Colorado Canyon Model Years: 2019 – 2021 2019 – 2021 VIN: from to All All All All Engine: LCV LCV MYB MYB Transmissions: Involved Region or Country Condition Cause North America Customers may comment on a vibration at idle while the transmission is in drive or reverse at 800 to 1000 RPM. The vibration may be more noticeable in reverse and during cold starts. Some customers may comment the vehicle has a short vibration during a launch. The cause of this concern may be internal to the torque converter. Correction: Using a Pico Oscilloscope Diagnostic Kit, mount the Pico Scope 3 axis vibration sensor (TA143) on the inner driver’s seat track with the hole or arrow on the sensor facing towards the front of the vehicle. Start the engine and place the vehicle in drive or reverse. While in the service bay with the vehicle not moving with the service brake applied increase the engine speed between 800 and 1000 RPM in an attempt to duplicate the vibration. Record a 30 second time frame of data. Review the Pico data and the data indicates an E2 vibration at 29 Hz between 1.1 mg to 12.7 mg or an E1 vibration at 14.1 Hz between 1.14 mg to 7.48 mg replace the transmission torque converter. Parts Information Description Torque Converter Part Number 24288046 QTY 1 Warranty Information For vehicles repaired under the Powertrain coverage, use the following labor operation. Reference the Applicable Warranties section of Investigate Vehicle History (IVH) for coverage information. Labor Operation Description Labor Time 8464810 Torque Converter Replacement. Use Publish Labor Time. Version History Version 2 Modified 06/24/2020 – Created on. 04/06/2021 – Added 2021 Model Years
SEOCONTENT-END
1 Associated Document
Manufacturer Communications
Bulletin No.: PIP5743A
Published date: 04/6/2021
https://www.nhtsa.gov/recalls?nhtsaId=10193431
“This site contains affiliate links for which OEMDTC may be compensated” |
- Scope 2205A 2 channel 25 MHz, 8-bit oscilloscope with probes
- 25 MHz bandwidth
- 1 GS/s sampling
- Advanced digital triggers
- Arbitrary waveform generator
- Oscilloscope probes NOT included
- Oscilloscope probes NOT included
- Scope 2205A-D2 2 channel 25 MHz, 8-bit oscilloscope (no probes)
- 25 MHz bandwidth
- Advanced digital triggers
- Arbitrary waveform generator
- Serial decoding
- PC Oscilloscope 4 channels with FG/AWG, 100MHz, Includes probes
- 100 MHz Bandwidth
- 4 Channel Oscilloscope
- 3.5 ns Rise time (calculated)
- 1 GS/s Sampling rate
- 2 analog/16 digital channels
- 50MHz bandwidth
- Built-in AWG in every model
- 1GSa/s; 32MS buffer
- Serial decoding/FFT advanced waveform analysis included!
- 2.4MSa/s, 12bits;
- DAQ card function;
- Cost-effective 8 channels oscilloscope for vehicle testing;
- 8 channels programmable generator which can analog signals of crankshaft, camshaft etc.
- Scope 4262 2 channel, 16-bit oscilloscope with probes
- PicoScope426216-bit Oscilloscope with probes
- Dual channel oscilloscope / spectrum analyzer
- 16 bit resolution
- Low distortion (102 dB SFDR)
- Scope 4824A 8 channel 20MHz USB 3
- 8-channel oscilloscope
- Includes 4 TA375 probes
- 20 MHz bandwidth
- 12-bit resolution
Last update on 2024-04-03 / Affiliate links / Images from Amazon Product Advertising API
This product presentation was made with AAWP plugin.